MIB
New updates of the MIB are sent regularly from MOC to SOC via GFTS and automatically distributed to all instrument teams, also via GFTS.
General logic for MIB applicability: Each LTP is usually split into 3 or 4 STP planning blocks, the blocks usually comprise between 3 and 6 STPs. The aim is that within each STP planning block, the same MIB applies for all the STPs. To make this possible, we target MIB updates so that they coincide with the first STP of the block.
Sometimes it is unavoidable that a MIB update takes place in the middle of the block. In this case, we only request a mid-block MIB update for IORGs of instruments directly impacted by the MIB change. This means that instrument teams not affected by the update do not need to wait for the new MIB before sending their IORGs and that they do not need to update IORGs already sent for the rest of that block. However, we do ask all that instrument IORGs use the new MIB at the start of the following block.
As several STPs are open at any time, and sometimes 2 blocks may be open, it is possible to have more than one CURRENT MIB for planning.
CURRENT and UPCOMING MIBs
STATUS | MIB name | Release notes | Corresponding FOP | Applicability |
---|---|---|---|---|
CURRENT | MIB__20230915M25823PFMS001_SOL | 25823PFM_CSW3.1.2_MAS7.33.pdf | 6.0 | All payload (except RPW) can use this version from STP281 to STP289 |
CURRENT | MIB__20231108M31323PFMS001_SOL | 6.0 | To be used by RPW from STP285 onwards (new sequences: AIWF033R, AIWF033S) All payload shall use this version (the latest) from STP290 onwards. | |
UPCOMING |
M | New MIB for STIX, to go with FSW update planned in STP296. All payload shall use this version from STP297 onwards (LTP14 block3). | ||
UPCOMING |
| New MIB MAG? New MIB PHI, pending successful test of new procedures on 18-19 Jan '24 |
MIB applicability
Once a planning block is open, you can continue to use the MIB with which the block was opened for the whole block, as long as there are no new MIB updates during that block affecting your instrument. However you must update to the new MIB for the next block.
As such there may be more than 1 applicable MIB per block/STP.
All Previously applicable MIB versions
Note: The MIB distributed on 20220105 had an error in the vdf file and in the name, as it was called version 20220205. MOC has confirmed the error made. As the rest of the MIB content is valid, the file will not be reissued or renamed.
But it may cause trouble for Instrument Teams looking for the most recent MIB through the filenaming.
MIB name | Release notes | Corresponding FOP | Applicability |
---|---|---|---|
MIB__20190411M10119PFMS001.SOL | 10119PFM_CSW3.0_MAS6.11.pdf | E2E-1 (and E2E-D1), May-June 2019 | |
MIB__20200124M02420PFMS001_SOL.zip | 35419PFM_CSW3.0.31p1_MAS6.51.pdf | FOP 3.0 | not yet defined |
MIB__20200131M03120PFMS001_SOL.zip | 03120PFM_CSW3.0.31p1_MAS6.51.pdf | FOP 3.0 | launch version, applicability not yet defined |
MIB__20200221M05220PFMS001_SOL.zip | 05220PFM_CSW3.0.31p1_MAS6.51.pdf | NECP version, applicability not formally defined (includes PHI FSW update at start NECP) | |
MIB__20200228M05920PFMS001_SOL.zip | 05920PFM_CSW3.0.31p1_MAS6.51.pdf | NECP version, applicability not formally defined (includes updates for RPW, STIX, EUI) | |
MIB__20200320M08020PFMS001_SOL.zip | 08020PFM_CSW3.0.31p1_MAS6.51.pdf MAS 6.51 (release notes) Scope: CSW 3.0.3p1 | NECP version, applicability not formally defined (includes updates in RPW sequences and EPD, SoloHI, MAG, RPW, STIX commands) | |
MIB__20200401M09220PFMS001_SOL.zip | 09220PFM_CSW3.0.3p1_MAS6.51.pdf | NECP version, applicability not formally defined Not implemented in SOC due to internal inconsistencies in MIB | |
MIB__20200408M09920PFMS001_SOL.zip | 09920PFM_CSW3.0.3p1_MAS6.51.pdf | NECP version, applicability not formally defined (includes removal of several deprecated instrument sequences and implementation of PHI database v4.4) | |
MIB__20200416M10720PFMS001_SOL.zip | 10720PFM_CSW3.0.3p1_MAS6.51.pdf | NECP version, applicability not formally defined (includes mainly updates for Metis) | |
MIB__20200505M12620PFMS001_SOL.zip | 12620PFM_CSW3.0.3p1_MAS6.51.pdf | Temporary version for Cruise STPs 100-101 (IORs can be sent based on this version, or the next one) | |
MIB__20200513M13420PFMS001_SOL.zip | 13320PFM_CSW3.0.3p1_MAS651.pdf MAS 6.51 (release notes) Scope: CSW 3.0.3p1 | Cruise STPs 100-101 (LTP1) and Cruise STPs 102-103 (LTP2) only still an update required for STIX | |
MIB__20200515M13620PFMS001_SOL.zip | 13620PFM_CSW3.0.3p1_MAS651.pdf | Cruise STPs 100-101 (LTP1) and Cruise STPs 102-103 (LTP2) | |
MIB__20200528M14920PFMS001_SOL.zip | 14920PFM_CSW3.0.3p1_MAS6.51.pdf | MIB update for PHI STP-100 (other payload can stick to previous version above) | |
MIB__20200603M15520PFMS001_SOL.zip | 15520PFM_CSW3.0.3p1_MAS6.51.pdf | MIB update for SWA and Metis (other payload can stick to 15 May version above) | |
MIB__20200618M17020PFMS001_SOL.zip | 17020PFM_CSW3.0.3p1_MAS6.51.pdf | MIB update for RPW beginning in STP-102 (other payload can stick to 15 May version above). | |
MIB__20200624M17620PFMS001_SOL.zip | 17620PFM_CSW3.0.3p1_MAS6.51.pdf MAS 6.51 (release notes) | MIB Update for SWA-PAS with applicability for STP-103. Note errors in AIWF050L & AIWF050M. Also update of MAG IDB to 5.4 (compatibiltiy implications for AIMF413). Baseline MIB from STP-104 onwards | |
MIB__20200710M19220PFMS001_SOL.zip | 19220PFM_CSW3.0.3p1_MAS6.51.pdf MAS 6.51 (release notes) | MIB Update with sequence updates SWA and RPW (also new SPICE CRPs). Applicable for SWA and RPW from STP-105 onwards | |
MIB__20200715M19720PFMS001_SOL.zip | 19720PFM_CSW3.0.3p1_MAS6.51.pdf MAS 6.51 (release notes) | MIB Update with sequence updates for EUI. Applicable for EUI from STP-107 onwards | |
MIB__20200723M20520PFMS001_SOL.zip | 20520PFM_CSW3.0.3p1_MAS6.51.pdf MAS 6.51 (release notes) | MIB Update with sequence updates for SWA. Applicable for SWA from STP-107 onwards | |
MIB__20200831M24420PFMS001_SOL.zip | MAS 7.21 (release notes) | New MIB for CSW update to CSW 3.1.1. Applicable for all payload from STP-113 onwards. Note that it does not include any payload updates so it should not affect IORs. If you do not receive the MIB in time for your STP-113 IOR delivery, it is acceptable to only implement it from STP-114 onwards). | |
MIB__20200908M25220PFMS001_SOL.zip | MAS 7.21 (release notes) | Final MIB for CSW3.1.1 with STIX sequence changes. Applicable for all payload from STP-115 onwards. | |
MIB__20200924M26820PFMS001_SOL.zip | MAS 7.21 (release notes) | MIB for STP-116 with updates to SWA Sequences. Applicable to STP-116 onwards for SWA and STP-117 onwards for all other instruments. | |
MIB__20201005M27920PFMS001_SOL.zip | 27920PFM_CSW3.1.1_MAS.7.21.pdf MAS 7.21 (release notes) | MIB for STP-118 with updates to PHI, EUI, STIX and SWA sequences. Applicable from STP-118 onwards for those 4 instruments and STP-119 onwards for all other instruments. | |
MIB__20201029M30320PFMS001_SOL.zip | MAS 7.21 (release notes) | MIB for STP-122 with updates to Metis, PHI, STIX and RPW sequences. Applicable from STP-122 onwards for those 4 instruments and STP-123 onwards for all other instruments. | |
MIB__20201113M31820PFMS001_SOL.zip | MAS 7.21 (release notes) | MIB for STP-124 with updates to SOC-plannability of STIX sequences and timing of EUI memory-swap sequences. Applicable for all payload from STP-124 onwards. | |
MIB__20201202M33720PFMS001_SOL.zip | MAS 7.21 (release notes) | MIB for STPs 127 to STP-131 (at least). Includes few sequence updates for EPD. Applicable for all payload from STP-127 onwards. | |
MIB__20210118M01821PFMS001_SOL.zip | MAS 7.33 (release notes) | MIB update affecting EUI sequences, associated with EUI SW update onboard. Applicable from STP-133 onwards for EUI. Unaffected instruments can use previous MIB for STP132-136. | |
MIB__20210204M03521PFMS001_SOL.zip | MAS 7.33 (release notes) | MIB update affecting PHI sequences, associated with PHI SW update onboard + new EPD sequence made SOC-plannable. Applicable from STP-136 onwards for PHI and EPD. | |
MIB__20210223M05421PFMS001_SOL.zip | MAS 7.33 (release notes) | MIB update affecting MAG and RPW sequences, needed from STP-138 onwards. Note MAG update actually came in 04221PFM_CSW3.1.2_MAS7.33.pdf | |
MIB__20210302M06121PFMS001_SOL.zip | MAS 7.33 (release notes) | MIB update affecting PHI sequences only, to be used by PHI team for STP140 and onwards | |
MIB__20210319M07821PFMS001_SOL.zip | MIB containing new RPW and SWA sequences. SWA sequences not yet in place in SOC model. Applicable from STP-143. | ||
MIB__20210330M08921PFMS001_SOL | Containing sequence updates for EPD, SWA, EUI, MAG, & Metis. MAG and Metis changes are simply connection test sequences. SoloHI changes listed in the notes are only version number increments relating to doucmentation updates at ESOC. No sequence content has changed. Applicable to all payload from STP-144. | ||
MIB__20210512M13221PFMS001_SOL.zip | STPs 150-153 Make IU-FCP-370 SOC Plannable TAC ROUTING RPW: new formal param values in AIWF037 | ||
MIB__20210519M13921PFMS001_SOL.zip | For STP150+ for RPW. AIWF038M (with new formal parameters) (and ADMS524B and ADMF548A) | ||
MIB__20210627M17821PFMS001_SOL.zip | For STP-155 and later. Changes to STIX covering its FSW update, as well as updated parameters for SWA and minor change for EUI. No change for the rest of the payload. | ||
MIB__20210708M18921PFMS001_SOL.zip | Required for SWA for STP-157 onwards (new sequence AIAF061B). Other instruments should use for STPs 158- to 61 if possible. | ||
MIB__20210806M21821PFMS001_SOL.zip | STIX/SPICE/PHI /SOLOHI/SWA update for STP 162 , delivered 6th August. Note that this is the MIB used for the start of Block 3 in STP-158 to 167 Schedule, so all payload instruments should use this for STPs 162 and 163 if at all possible. | ||
MIB__20210915M25821PFMS001_SOL.zip | MIB updates for METIS command reduction OBCPs. Applicable from 167 version 2 | ||
MIB__20210920M26321PFMS001_SOL.zip | 26321PFM_CSW3.1.2_MAS7.33.pdf | EPD tidy up for September (for use 169) New RPW sequences (for use 169+) | |
MIB__20211008M28121PFMS001_SOL.zip | New RPW burst mode sequences (for STP 171 targeted MIB) PHI 2 new sequences + 1 sequence update (for use in STP172) Applicable for all payload from STP172 onwards | ||
MIB__20211028M30121PFMS001_SOL.zip | 30121PFM_CSW3.1.2_MAS7.33.pdf | STPs 181 and 182 opened on this MIB. Instruments should should IORs on this MIB for 181-182 unless they require the next release Changes include: RPW sequence updates and EUI FSW related changes For RPW -needed for STP179, EUI -no effect on SOC | |
MIB__20211118M32221PFMS001_SOL.zip | 32221PFM_CSW3.1.2_MAS7.33.pdf | 5.0 | Changes: METIS & RPW updates for STP 180. Required for these 2 instrument. All instruments can send IORs on this MIB from 181-182. STPs 183-187 will be opened on this MIB ( MIB__20211118M32221PFMS001_SOL ) All instruments (except SPICE, see below) can use this MIB__20211118M32221PFMS001_SOL for 181-187 for IORs. |
MIB__20211130M33421PFMS001_SOL.zip | 5.0 | Required by SPICE from 182 onwards
SOC will update to this MIB from STP-182 STPs 183-187 will be opened on MIB__20211118M32221PFMS001_SOL but updated to this MIB (MIB__20211130M33421PFMS001_SOL). | |
MIB__20220112M01222PFMS001_SOL.zip | 01222PFM_CSW3.1.2_MAS7.33.pdf | 5.0 | All instruments should use this MIB from STP188 onwards. Required by PHI (SPICE, Metis) from STP187. Includes updates that were delivered in several different MIBs (only applied in SOC now): |
MIB__20220202M03322PFMS001_SOL.zip | 5.0 | All instruments should use this MIB from STP191 onwards. 4 PHI new sequences to be applied at SOC and usable in IORs. SPICE LUTs updated. Valid from 190 (for SPICE) . | |
MIB__20220112M01222PFMS001_SOL.zip | 01222PFM_CSW3.1.2_MAS7.33.pdf | 5.0 | All instruments should use this MIB from STP188 onwards. Required by PHI (SPICE, Metis) from STP187. Includes updates that were delivered in several different MIBs (only applied in SOC now): |
MIB__20220202M03322PFMS001_SOL.zip | 5.0 | All instruments should use this MIB from STP191 onwards. 4 PHI new sequences to be applied at SOC and usable in IORs. SPICE LUTs updated. Valid from 190 (for SPICE) . | |
MIB__20220224M05522PFMS001_SOL.zip | 5.0 | SWA changes, applicable for all instruments from STP-194 onwards (or later MIB releases) | |
MIB__20220306M06522PFMS001_SOL.zip | 5.0 | Applicable for PHI from STP195 onwards. PHI update incl. new procedure IP-FCP-021 (+ can be used by other instruments) | |
MIB__20220505M12522PFMS001_SOL.zip | 12522PFM_CSW3.1.2_MAS733.pdf | 6.0 | Applicable for Metis and PHI from STP-204 onwards. Applicable for all instruments from STP-205 onwards. METIS HVU ramp up update after UVDA test (FCR-1016)/METIS HVU ramp down update after UVDA test (FCR-1018): update required for resuming UV operations. Additional Op/Non-Op config for PHI around annealing. |
MIB__20220520M13922PFMS001_SOL.zip | 6.0 | Applicable for Metis and SWA from STP-206 onwards. All instruments shall use this version from STP-210 onwards until further notice | |
MIB__20220912M25522PFMS001_SOL.zip | 25522PFM_CSW3.1.2_MAS7.33.pdf | 6.0 | PHI FSW applicable for STP223 and onwards EPD Add two new sequences to open/close SIS IRIS from the MPS (not plannable from IORs) EUI, procedure updates to allow EUI to have 1 IOR per day. |
MIB__20220912M25522PFMS001_SOL.zip | 25522PFM_CSW3.1.2_MAS7.33.pdf | 6.0 | All instruments shall use this version from STP-226 onwards until further notice EPD Add two new sequences to open/close SIS IRIS from the MPS (not plannable from IORs) EUI, procedure updates to allow EUI to have 1 IOR per day. PHI FSW applicable for STP223 and onwards |
30 November, 2022 will not be used by SOC. Not applicable to any STP/instruments | |||
MIB__20230120M02023PFMS001_SOL.zip | All instruments to use this version from STP-244 onwards until further notice: New PHI sequences. RPW formal parameters (AIWF037K) New METIS sequences (AITF490A/B, AITF502A) | ||
MIB__20230313M07223PFMS001_SOL.zip | 6.0 | All instruments shall use this version from STP-251 onwards until further notice. | |
MIB__20230710M19123PFMS001_SOL.zip | 19123PFM_CSW3.1.2_MAS7.33.pdf | 6.0 | All instruments shall use this version from STP-269 onwards until further notice. |
MIB__20230809M22123PFMS001_SOL.zip | 21223PFM_CSW3.1.2_MAS7.33.pdf | 6.0 | All instruments shall use this version from STP-277 onwards until further notice. |
MIB__20230915M25823PFMS001_SOL.zip | 25823PFM_CSW3.1.2_MAS7.33.pdf | 6.0 | For STP278 RPW new sequence AIWF033Q SWA change fixed parameter into formal parameter RPW and SWA shall use this version from STP278 All other instruments should use this from STP281. |
MIB__20231108M31323PFMS001_SOL.zip | 31323PFM_CSW3.1.2_MAS7.33.pdf | 6.0 | RPW shall use this version from STP-285 onwards, other payload shall use this version from STP-290 until further notice. |
FOP