Observation configuration and data rate calculation
Observing mode | Target | Line List | #Line Profiles | #Px/Profile | # Intensities | Slit (") | Exp.time | # Mirror Pos | Step size | Tilt time | FOV (") | Data cube (px) | Duration | Repeats | Calc. Data Vol | Total Data Vol | Total Duration | Data rate | Comments | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
= study | (max=32) | 2/4/6/30 | (s) | =#exposures | (arcsecs) | (secs) | X | Y | X | Y | Z | (min) | (MB) | Compressed (MB) | (min) | (kbits/s) | ||||||||
Limb | Low corona above limb | C III, O VI, Ne VIII profiles + 3intensities | 3 | 32 | 3 | 4 | 60 | 240 | 4 | 0.14 | 960 | 840 | 240 | 800 | 102 | 240.6 | 1 | 39.17 | 4.545 | 240.6 | 2.52 | |||
16' | 14' | scan direction | along slit | spectral dimension |
Spectral-line performance
Line-SNR and spatial resolution combinations:
line-SNR >10 at 4"x2" in C-III, O-VI, Ne-VIII and Mg-IX (in ARs)
1 Comment
David Williams
Will update this line list with the information originally in 1.1.2.4 from Alessandra:
Key SPICE lines to be included: H I 1025 Å, C III 977 Å, O VI 1032 Å, O VI 1037 Å, Ne VIII 770 Å, Mg IX 706 Å – 6 lines (3 profiles+3 intensities) for Limb